Typical Cable Applications:
Suitable for use in fire risk locations: high rise buildings, sub-surface, underground & metro systems
Plain solid copper conductors, PE insulation, unit twin construction, polyester core wrap, fire retardant tape, drain wire, electrical screen, low smoke zero halogen sheath.
Compliant with British Telecom Standard CW1600.
| I-0003-P050-001-00-T-1600 |
3 |
0.50 |
0.60 |
4.8 |
97.8 |
80 |
500 |
| I-0040-P050-001-00-T-1600 |
40* |
0.50 |
0.90 |
15.0 |
97.8 |
80 |
500 |
| I-0100-P050-001-00-T-1600 |
100* |
0.50 |
1.50 |
27.0 |
97.8 |
80 |
500 |
| I-0320-P050-001-00-T-1600 |
320* |
0.50 |
2.20 |
39.5 |
97.8 |
80 |
500 |
Note 1: * These cables contain a 1.38 mm PVC insulated Earth wire
Note 2: Available in pair range 2 - 320 pair
TACW conductors of 0.5 mm, PVC insulation, unit twin construction, polyester core wrap,
fire retardant tape, low smoke zero halogen sheath.
Compliant with Saudi Arabian Telecom Standard MAT1401
| I-0010-P050-001-00-T-1401 |
10 |
0.50 |
0.90 |
9.0 |
92 |
75 ± 2 |
22 |
| I-0030-P050-001-00-T-1401 |
30 |
0.50 |
1.10 |
13.0 |
92 |
75 ± 2 |
22 |
| I-0050-P050-001-00-T-1401 |
50 |
0.50 |
1.20 |
16.0 |
92 |
75 ± 2 |
22 |
| I-0100-P050-001-00-T-1401 |
100 |
0.50 |
1.30 |
20.0 |
92 |
75 ± 2 |
|
Note: Available in pair range 6 - 300 pairs
Plain solid copper conductors of 0.5mm, PE insulation, pair construction in concentric layers.
1 or more core wrap tapes, longitudinally applied aluminium-copolymer tape and low smoke zero halogen sheath.
Compliant with Spanish ICT standards
| I-0025-P050-001-45-AT-ICT |
26 |
0.50 |
1.2 |
12.0 |
91 |
52 |
45 |
21 |
100 |
| I-0050-P050-001-45-AT-ICT |
51 |
0.50 |
1.2 |
16.0 |
91 |
52 |
| I-0075-P050-001-45-AT-ICT |
76 |
0.50 |
1.2 |
19.0 |
91 |
52 |
| I-0100-P050-001-45-AT-ICT |
101 |
0.50 |
1.2 |
21.0 |
91 |
52 |
OUTSIDE PLANT PRIMARY CABLES
Typical Cable Applications:
Outside Plant (OSP) Cables used primarily in the Primary or Exchange (‘E’-side) Network.
Plain solid copper conductors of 0.4 and 0.6 mm, PE insulation, pair construction in concentric layers,
1 or more core wrap tapes, service quad, HDPE sheath incorporating a longitudinally applied aluminium-copolymer tape.
Compliant with Italian Telecom Standard (Italian Standard) CT-1240
| E-1200-P040-001-50-AP-1240 |
1200 |
0.40 |
2.50 |
62.5 |
150 |
55 |
50 |
27 |
140 |
| E-1600-P040-001-50-AP-1240 |
1600 |
0.40 |
2.70 |
72.0 |
150 |
55 |
| E-2400-P040-001-50-AP-1240 |
2400 |
0.40 |
3.10 |
85.2 |
150 |
55 |
| E-0800-P060-001-50-AP-1240 |
800 |
0.60 |
2.20 |
64.0 |
66.6 |
55 |
| E-1200-P060-001-50-AP-1240 |
1200 |
0.60 |
2.50 |
79.0 |
66.6 |
55 |
Plain solid copper conductors of 0.4 and 0.6 mm, PE insulation, pair construction in concentric layers,
1 or more core wrap tapes, service quad, HDPE sheath incorporating a longitudinally applied aluminium-copolymer tape,
helical steel tape armour, HDPE sheath.
Compliant with Italian Telecom Standard (Italian Standard) CT-1240.
| E-0100-P040-001-50-AP-1240HP |
100 |
0.40 |
1.80 |
21.6 |
150 |
55 |
50 |
27 |
140 |
| E-0200-P040-001-50-AP-1240HP |
200 |
0.40 |
1.80 |
29.1 |
150 |
55 |
| E-0800-P040-001-50-AP-1240HP |
800 |
0.40 |
2.20 |
51.4 |
150 |
55 |
| E-1200-P040-001-50-AP-1240HP |
1200 |
0.40 |
2.50 |
62.5 |
150 |
55 |
| E-2400-P040-001-50-AP-1240HP |
2400 |
0.40 |
3.10 |
85.2 |
150 |
55 |
| E-0100-P060-001-50-AP-1240HP |
100 |
0.60 |
1.80 |
29 |
66.6 |
55 |
| E-0200-P060-001-50-AP-1240HP |
200 |
0.60 |
1.90 |
37.3 |
66.6 |
55 |
| E-0800-P060-001-50-AP-1240HP |
800 |
0.60 |
2.70 |
70.5 |
66.6 |
55 |
| E-1200-P060-001-50-AP-1240HP |
1200 |
0.60 |
3.00 |
87 |
66.6 |
55 |
Plain solid copper conductors of 0.5mm, PE insulation, pair construction in concentric layers.
1 or more core wrap tapes, longitudinally applied aluminium-copolymer tape and PE sheath.
Compliant with Spanish ICT standards.
| E-0025-P050-001-45-AP-ICT |
26 |
0.50 |
1.2 |
12.0 |
93 |
52 |
45 |
21 |
100 |
| E-0050-P050-001-45-AP-ICT |
51 |
0.50 |
1.2 |
16.0 |
93 |
52 |
| E-0075-P050-001-45-AP-ICT |
76 |
0.50 |
1.2 |
19.0 |
93 |
52 |
| E-0100-P050-001-45-AP-ICT |
101 |
0.50 |
1.2 |
21.0 |
93 |
52 |
Plain solid copper conductors of 0.5 mm, PE insulation, quad constructions, a perforated wire of solid copper with a diameter of 0.5 mm,
Polyurethane filled, 4 x TACW continuity wires with a diameter of 0.41 mm, PE sheath, layer of galvanized steel wires, and green PE sheath.
Compliant with Netherlands Standard PTT NORM 92.
| E-0012-Q050-001-40-PGP-NM92 |
6 |
0.50 |
1.20 |
17.0 |
93 |
40 |
40 |
15 |
| E-0030-Q050-001-40-PGP-NM92 |
15 |
0.50 |
1.50 |
21.5 |
93 |
40 |
| E-0050-Q050-001-40-PGP-NM92 |
25 |
0.50 |
1.50 |
30.0 |
93 |
40 |
Plain solid copper conductors of 0.4, 0.6, and 0.8 mm (Serial 89), PE insulation, pair construction in concentric layers,
1 or more core wrap tapes, continuity wire, HDPE sheath incorporating a longitudinally applied aluminium-copolymer tape.
Compliant with French Telecom Standard (Normes France) NF C 93-526 & NF C 93-527-7.
| E-0014-P040-001-00-AP-93526 |
14 |
0.40 |
1.30 |
7.9 |
293.6 |
55 |
52.5 |
500 |
250 |
| E-0056-P040-001-00-AP-93526 |
56 |
0.40 |
1.50 |
13.0 |
293.6 |
55 |
52.5 |
500 |
250 |
| E-0014-P060-001-00-AP-93526 |
14 |
0.60 |
1.40 |
10.8 |
130.5 |
55 |
52.5 |
500 |
250 |
| E-0056-P060-001-00-AP-93526 |
56 |
0.60 |
1.60 |
17.7 |
130.5 |
55 |
52.5 |
500 |
250 |
| E-0008-P060-001-00-AP-93526 |
8 |
0.80 |
1.40 |
10.3 |
73.4 |
55 |
52.5 |
250 |
125 |
| E-0028-P060-001-00-AP-93526 |
28 |
0.80 |
1.60 |
16.5 |
73.4 |
55 |
52.5 |
250 |
125 |
Plain solid copper conductors, solid PE insulation (0.4 mm cdr), foamskin PE insulation (0.6 & 0.8 mm cdr), pair construction in concentric layers, petroleum jelly filled, 2 x core wrap tapes, continuity wire, corrugated steel tape armour, HDPE sheath.
Options: Helical steel tape armour (Series 75) compliant to NF C 93-526 & NF C 93-527.
Compliant with French Telecom Standard (Normes France) NF C 93-527-9 & NF C 93-527-1
| E-0112-P040-001-00-SP-93527 |
112 |
0.40 |
2.00 |
22.0 |
293.6 |
55 |
500 |
250 |
| E-0112-P060-001-00-SP-93527 |
112 |
0.60 |
2.20 |
26.4 |
130.5 |
55 |
500 |
250 |
| E-0112-P080-001-00-SP-93527 |
112 |
0.80 |
2.20 |
34.4 |
73.4 |
55 |
250 |
125 |
Note: Single armoured version available in pair range 8 - 1792, double armoured 28 - 224
Plain solid copper conductors, PE insulation, 25 pair unit twin construction,
dry core, polyester/paper core wrap, Aluminium - copolymer moisture barrier, black PE sheath.
Compliant with Bahrain Telecommunications Specification BTC1961 & British Telecom Standard CW1171.
| E-4800-P032-001-00-D-AP-1171 |
4800 |
0.32 |
2.70 |
76.0 |
223 |
53 |
275 |
| E-1000-P040-001-00-D-AP-1171 |
1000 |
0.40 |
2.30 |
51.5 |
143 |
53 |
275 |
| E-2400-P040-001-00-D-AP-1171 |
2400 |
0.40 |
2.70 |
75.0 |
143 |
53 |
275 |
| E-0100-P050-001-00-D-AP-1171 |
100 |
0.50 |
1.70 |
23.5 |
91 |
56 |
275 |
| E-0800-P063-001-00-D-AP-1171 |
800 |
0.63 |
2.70 |
70.5 |
58 |
56 |
275 |
| E-0100-P090-001-00-D-AP-1171 |
100 |
0.90 |
2.00 |
38.0 |
28 |
59 |
275 |
Note: Cables available in pair range 50 - 4800
Plain solid copper conductors, cellular PE insulation, 25 pair unit twin construction,
dry core, polyester/paper core wrap, Aluminium - copolymer moisture barrier, black PE sheath.
Compliant with Cable & Wireless Specification CW0006 & British Telecom Standard CW1224.
| E-4800-P032-001-00-D-AP-1224 |
4800 |
0.32 |
2.70 |
76.0 |
223 |
53 |
275 |
| E-2400-P040-001-00-D-AP-1224 |
2400 |
0.40 |
2.60 |
70.0 |
143 |
53 |
275 |
| E-0100-P050-001-00-D-AP-1224 |
100 |
0.50 |
1.70 |
22.0 |
91 |
56 |
275 |
| E-2000-P050-001-00-D-AP-1224 |
2000 |
0.50 |
2.70 |
75.0 |
91 |
56 |
275 |
| E-0800-P063-001-00-D-AP-1224 |
800 |
0.63 |
2.50 |
61.0 |
58 |
56 |
275 |
| E-0100-P090-001-00-D-AP-1224 |
100 |
0.90 |
1.90 |
32.5 |
28 |
59 |
275 |
Note: Cables available in pair range 50 - 4800
OUTSIDE PLANT SECONDARY CABLE
Typical Cable Applications:
Outside Plant (OSP) Cables used primarily in the Secondary or Distribution (‘D’-side) Network
A-2Y(L)2Y St III Bd Local Cable
Plain solid copper conductors of 0.4, 0.6 or 0.8 mm, solid PE insulation, quad construction in concentric layers,
plastic core wrap tape, PE sheath incorporating a longitudinally applied aluminium-copolymer tape.
Compliant with German Telecom Standard (Verband der Electrotechnik) VDE 0816 Part 1.
Options: Steel tape Armour - A-2Y(L)2Y2BY, Steel Wire Armour - A-2Y(L)2YR
| E-0100-P040-001-00-D-AP-0816 |
100 |
0.40 |
1.80 |
21.0 |
300 |
50 |
800 |
800 |
| E-0100-P060-001-00-D-AP-0816 |
100 |
0.60 |
2.00 |
25.0 |
130 |
52 |
800 |
800 |
| E-0050-P080-001-00-D-AP-0816 |
50 |
0.80 |
2.00 |
26.0 |
73.2 |
55 |
800 |
800 |
Note: Cables available in pair range 8 - 168
Plain solid copper conductors, cellular PE insulation, 10 pair unit twin construction, petroleum jelly filled, paper core wrap, PE sheath.
Compliant with Cable & Wireless Specification CW0011 (screened version) & British Telecom Standard CW1128.
Options: Moisture Barrier (CW1179), Steel Wire Armouring (CW1198) and Aerial Self Supporting (CW1252).
| E-0100-P040-001-00-F-P-1128 |
100 |
0.40 |
1.3 |
18.5 |
20.0 |
25.3 |
26.8 |
143 |
56 |
| E-0100-P050-001-00-F-P-1128 |
100 |
0.50 |
1.4 |
22.0 |
23.5 |
29.0 |
30.5 |
91 |
56 |
| E-0100-P060-001-00-F-P-1128 |
100 |
0.60 |
1.6 |
32.0 |
33.5 |
40.2 |
41.7 |
63 |
42 |
| E-0100-P063-001-00-F-P-1128 |
100 |
0.63 |
1.5 |
27.5 |
29.0 |
35.5 |
37.0 |
58 |
56 |
| E-0100-P090-001-00-F-P-1128 |
100 |
0.90 |
1.7 |
36.0 |
37.5 |
44.4 |
45.9 |
28 |
59 |
Note: Cables available in pair range 2 - 100
Plain solid copper conductors, solid PE insulation, 10 pair unit twin construction,
petroleum jelly filled, paper core wrap, PE sheath.
Options: Moisture Barrier (CW1179), Steel Wire Armouring (CW1198) and Aerial Self Supporting (CW1252).
Compliant with British Telecom Standard CW1326.
| E-0010-P050-001-00-F-P-1326 |
10 |
0.50 |
1.20 |
12.0 |
91 |
56 |
275 |
| E-0020-P050-001-00-F-P-1326 |
20 |
0.50 |
1.30 |
15.0 |
91 |
56 |
275 |
| E-0050-P050-001-00-F-P-1326 |
50 |
0.50 |
1.40 |
19.5 |
91 |
56 |
275 |
| E-0100-P050-001-00-F-P-1326 |
100 |
0.50 |
1.50 |
25.0 |
91 |
56 |
275 |
Note: Cables available in pair range 2 - 100
Plain solid copper conductors of 0.4, 0.51, 0.64 or 0.9 mm, foam skin PE insulation, twisted pair construction in concentric layers,
petroleum jelly filled, 1 or more core wrap tapes, PE sheath incorporating a longitudinally applied corrugated aluminium-copolymer tape.
Compliant with American National Standards Institute / Insulated Cable Engineers Association (ANSI/ICEA) S-84-608-2007.
| E-0050-P040-001-00-F-P-PE89 |
50 |
0.40 |
14.0 |
144.2 |
52 ± 4 |
52 ± 2 |
145 |
7.0 |
| E-0100-P050-001-00-F-P-PE89 |
100 |
0.50 |
22.0 |
89.5 |
52 ± 4 |
52 ± 2 |
145 |
5.6 |
| E-0100-P064-001-00-F-P-PE89 |
100 |
0.64 |
27.0 |
56.6 |
52 ± 4 |
52 ± 2 |
145 |
4.5 |
| E-0100-P090-001-00-F-P-PE89 |
100 |
0.90 |
38.0 |
28.0 |
52 ± 4 |
52 ± 2 |
145 |
3.2 |
Note: Cables available in pair range 6 - 2400
Option: Available as type PE-89 - Aerial Self Supporting compliant with ANSI/ICEA S-84-608-2007, RDUP 7 CFR 1755.890 & ANSI/ICEA S-85-625-2007 (support member)
Type PE-22 distribution cable
Plain solid copper conductors of 0.4, 0.51, 0.64 or 0.9 mm, solid PE insulation, twisted pairs, concentric up to 25 pairs, unit construction thereafter.
1 or more core wrap tapes, PE sheath incorporating a longitudinally applied corrugated aluminium-copolymer tape>
Compliant with American National Standards Institute / Insulated Cable Engineers Association (ANSI/ICEA) S-85-625-2007.
Cables compliant with ICT normative Infraestructura común de telecomunicaciones.
| E-0050-P040-001-00-D-MP-PE22 |
50 |
0.40 |
14.0 |
144.2 |
52 ± 4 |
52 ± 2 |
145 |
7.0 |
| E-0100-P050-001-00-D-MP-PE22 |
100 |
0.50 |
21.0 |
89.5 |
52 ± 4 |
52 ± 2 |
145 |
5.6 |
| E-0100-P064-001-00-D-MP-PE22 |
100 |
0.64 |
26.0 |
56.6 |
52 ± 4 |
52 ± 2 |
145 |
4.5 |
| E-0100-P090-001-00-D-MP-PE22 |
100 |
0.90 |
34.0 |
28.0 |
52 ± 4 |
52 ± 2 |
145 |
3.2 |
Note: Cables available in pair range 6 - 2400
Option: Available as aerial self supporting cable